β¬’ DragonFlyBSD Kernel Audit
← triage Β· dashboard
DF-4936

dig_encoder_sel_to_atom dead 7-case mapping discarded by literal 'return 0' (v1 twin of DF-2030; file additionally dead code on genuine hardware)

Summary

Byte-identical v1 twin; the v1 table binds only via the fallback parser taken solely for sub-2.2 ATOM ROMs (never genuine DCE11.2). Same upstream cleanup.

Discussion (0)

No comments yet.

PoC verification

Evidence pack

findings/poc/DF-4936 Β· 1 files
FileTypeDescriptionSize
verdict.json file 750 B view raw

Fix verification

not_testable
per-fix-DF-4936

Confirmed kernel references

Detail

Exploit chain

none - dead code on genuine hardware

Evidence (decisive lines)

findings/poc/DF-4936/ (this verdict)

Verdict

Dead-code trap, doubly gated (Info): byte-identical v1 twin of the v2 dead return-0 switch - and the v1 table is only bound via the fallback parser taken solely for sub-2.2 ATOM ROMs (never true for genuine DCE11.2). Intended encoding per upstream. Same delete-the-dead-switch fix.