DF-0342
in6_update_ifa inconsistent error handling on multicast group joins
Summary
Solicited-node join failure fatal: in6_purgeaddr+return(:1118-1127). All-nodes/node-info join failure: LOG_WARNING+continue(:1151-1175,:1200-1207). Address installed+routed but missing mandatory ff02::1 membership -> broken ND/MLD. Transient ENOMEM trigger.
Discussion (0)
PoC verification
Evidence pack
findings/poc/DF-0342 Β· 1 files| File | Type | Description | Size | |
|---|---|---|---|---|
| manifest.json | file | 384 B | view raw |
Fix verification
not_testablebaseline reproducedβ patch + rebuild βpatched clean
recommended fix identified; fix.diff not authored/validated in this batch
recommended fix identified; fix.diff not authored/validated in this batch
combined build rc=0
Confirmed kernel references
β
Detail
Exploit chain
none (Info severity)
Evidence (decisive lines)
Source-confirmed at sys/netinet6/in6.c:1144: in6_update_ifa inconsistent error handling on multicast group joins
Verified recommended fix
Source-confirmed at sys/netinet6/in6.c:1144: in6_update_ifa inconsistent error handling on multicast group joins
Verdict
Source-confirmed at sys/netinet6/in6.c:1144: in6_update_ifa inconsistent error handling on multicast group joins
No comments yet.