β¬’ DragonFlyBSD Kernel Audit
← triage Β· dashboard
DF-0342

in6_update_ifa inconsistent error handling on multicast group joins

Summary

Solicited-node join failure fatal: in6_purgeaddr+return(:1118-1127). All-nodes/node-info join failure: LOG_WARNING+continue(:1151-1175,:1200-1207). Address installed+routed but missing mandatory ff02::1 membership -> broken ND/MLD. Transient ENOMEM trigger.

Discussion (0)

No comments yet.

PoC verification

Evidence pack

findings/poc/DF-0342 Β· 1 files
FileTypeDescriptionSize
manifest.json file 384 B view raw

Fix verification

not_testable
baseline reproduced→ patch + rebuild →patched clean

recommended fix identified; fix.diff not authored/validated in this batch

recommended fix identified; fix.diff not authored/validated in this batch
combined build rc=0

Confirmed kernel references

β€”

Detail

Exploit chain

none (Info severity)

Evidence (decisive lines)

Source-confirmed at sys/netinet6/in6.c:1144: in6_update_ifa inconsistent error handling on multicast group joins

Verified recommended fix

Source-confirmed at sys/netinet6/in6.c:1144: in6_update_ifa inconsistent error handling on multicast group joins

Verdict

Source-confirmed at sys/netinet6/in6.c:1144: in6_update_ifa inconsistent error handling on multicast group joins